Engineers R World – Thermodynamics Formula Sheet | engineersrworld.com | engineersrworld@gmail.com | WhatsApp: +91 89197 41799
Quick answer: This thermodynamics formula sheet gives you every formula you need for engineering exams and GATE in one place: first law, steady flow, ideal gas processes, second law and entropy, steam properties, and the Otto, Diesel, Brayton, Rankine and refrigeration cycles. Each formula comes with a one-line meaning in simple words, so you know when to use it.
Sign rule used on this page: heat going into the system is positive (+Q). Work done by the system is positive (+W). So a turbine has +W and a compressor has −W. Always use absolute pressure and temperature in kelvin in gas formulas.
Which formula do I start with?
| If the question says… | Start with |
|---|---|
| Gas heated or compressed in a closed cylinder | First law: Q = ΔU + W (Section 2) |
| Steam or gas flowing through a turbine, compressor, nozzle or heat exchanger | Steady flow energy equation (Section 3) |
| Expansion or compression with PVn = constant | Process table (Section 5) |
| “Is this engine or refrigerator possible?” | Carnot efficiency and entropy (Section 6) |
| Steam at a given pressure with dryness fraction x | Steam formulas, h = hf + x·hfg (Section 7) |
| Efficiency of an engine cycle or COP of a refrigerator | Cycle formulas (Section 8) |
1. Basic terms and units
| Quantity | Formula | In simple words |
|---|---|---|
| Absolute pressure | Pabs = Pgauge + Patm | Gas formulas need absolute pressure, not the gauge reading. |
| Vacuum pressure | Pabs = Patm − Pvacuum | Below atmosphere, subtract the vacuum reading. |
| Pressure of a liquid column | P = ρ g h | Pressure increases with depth. |
| Temperature | T (K) = t (°C) + 273 | Use kelvin in gas laws, Carnot and entropy. |
| Specific volume | v = V / m = 1 / ρ | Volume occupied by 1 kg of substance. |
| Handy conversions | 1 bar = 100 kPa, 1 atm = 101.325 kPa, 1 kWh = 3600 kJ | Convert units before you substitute. |
| Zeroth law | If A and B are each in thermal equilibrium with C, then A and B are in equilibrium with each other | This is why a thermometer works. |
| Boundary work | W = ∫ P dV | Area under the P–V graph. |
2. First law of thermodynamics (closed system)
| Quantity | Formula | In simple words |
|---|---|---|
| First law | Q = ΔU + W | Heat added either raises internal energy or comes out as work. |
| Per kg of substance | q = Δu + w | Same equation, for 1 kg. |
| Complete cycle | ΣQ = ΣW | The system returns to its start, so ΔU = 0 and net heat = net work. |
| Enthalpy | H = U + PV, h = u + Pv | Useful “total energy” for flowing fluids. |
| Constant-volume heating | Q = ΔU | Volume fixed, so no work is done. |
| Constant-pressure heating | Q = ΔH | Heat added at constant pressure equals the enthalpy rise. |
| Perpetual motion machine of the first kind (PMM1) | Impossible | It would create energy from nothing, which breaks the first law. |
3. Steady flow devices (open system)
| Quantity | Formula | In simple words |
|---|---|---|
| Mass balance | ṁ = A V / v (in = out) | The same mass enters and leaves every second. |
| Steady flow energy equation (SFEE) | Q − W = ṁ[(h2 − h1) + (V2² − V1²)/2 + g(z2 − z1)] | Energy in = energy out for a moving stream. Q and W are in kW when ṁ is in kg/s. |
| Turbine (adiabatic) | W = ṁ (h1 − h2) | Work out = drop in enthalpy. |
| Compressor (adiabatic) | W = ṁ (h2 − h1) (work input) | Work in = rise in enthalpy. |
| Pump | W = ṁ v (P2 − P1) | Liquids barely change volume, so this is small. |
| Nozzle | V2 = √[2000 (h1 − h2)] m/s, with h in kJ/kg | Enthalpy drop becomes speed. The 1000 converts kJ to J. Inlet speed is assumed small. |
| Throttling valve | h1 = h2 | Pressure drops but enthalpy stays the same. |
| Heat exchanger | ṁhot(hhot,in − hhot,out) = ṁcold(hcold,out − hcold,in) | Heat lost by the hot stream = heat gained by the cold stream. |
| Boiler or condenser | Q = ṁ (hout − hin) | No work, so heat equals enthalpy change. |
4. Ideal gas relations
| Quantity | Formula | In simple words |
|---|---|---|
| Ideal gas law | PV = mRT, or Pv = RT | Connects pressure, volume and temperature. |
| Gas constant | R = Ru / M, with Ru = 8.314 kJ/kmol·K | Each gas has its own R. For air, R = 0.287 kJ/kg·K. |
| Specific heats | cp − cv = R | cp is always bigger than cv. |
| Ratio of specific heats | γ = cp / cv | For air γ = 1.4. |
| In terms of γ | cv = R / (γ − 1), cp = γR / (γ − 1) | Find cp and cv when only R and γ are given. |
| Air at room temperature | cp = 1.005, cv = 0.718 kJ/kg·K | Standard values used in most problems. |
| Change in internal energy | ΔU = m cv (T2 − T1) | True for any process of an ideal gas, not only constant volume. |
| Change in enthalpy | ΔH = m cp (T2 − T1) | True for any process of an ideal gas, not only constant pressure. |
| Compressibility factor | Z = Pv / (RT) | Z = 1 means ideal gas. The further from 1, the more real the gas. |
| Van der Waals equation | (P + a/v²)(v − b) = RT | Real-gas correction for molecular attraction (a) and size (b). |
5. Ideal gas processes
| Process | Condition | State relation | Work W | Heat Q |
|---|---|---|---|---|
| Constant volume (isochoric) | V = constant | P1/T1 = P2/T2 | 0 | m cv (T2 − T1) |
| Constant pressure (isobaric) | P = constant | V1/T1 = V2/T2 | P (V2 − V1) = mR (T2 − T1) | m cp (T2 − T1) |
| Constant temperature (isothermal) | T = constant | P1V1 = P2V2 | mRT ln(V2/V1) = mRT ln(P1/P2) | Q = W (ΔU = 0) |
| Reversible adiabatic (isentropic) | Q = 0 | P1V1γ = P2V2γ T2/T1 = (P2/P1)(γ−1)/γ = (V1/V2)γ−1 | (P1V1 − P2V2)/(γ − 1) = mR (T1 − T2)/(γ − 1) | 0 |
| Polytropic | PVn = constant | P1V1n = P2V2n T2/T1 = (P2/P1)(n−1)/n | (P1V1 − P2V2)/(n − 1) | W × (γ − n)/(γ − 1) |
| Free expansion into vacuum | Nothing pushes back | T2 = T1 | 0 | 0 |
Easy way to remember: the polytropic equation PVn = C covers all the others. n = 0 gives constant pressure, n = 1 gives isothermal, n = γ gives adiabatic, and n = ∞ gives constant volume.
6. Second law, Carnot cycle and entropy
| Quantity | Formula | In simple words |
|---|---|---|
| Heat engine efficiency | η = Wnet / QH = 1 − QL / QH | Fraction of the heat taken in that becomes work. |
| Refrigerator | COPR = QL / W = QL / (QH − QL) | Cooling obtained for each unit of work given. |
| Heat pump | COPHP = QH / W, and COPHP = COPR + 1 | Heating obtained for each unit of work given. |
| Carnot engine | η = 1 − TL / TH | The best possible efficiency between two temperatures. Use kelvin. |
| Carnot refrigerator | COP = TL / (TH − TL) | Upper limit for any refrigerator. |
| Carnot heat pump | COP = TH / (TH − TL) | Upper limit for any heat pump. |
| Clausius inequality | ∮ δQ / T ≤ 0 | Equal to 0 for a reversible cycle, less than 0 for an irreversible one, more than 0 is impossible. |
| Entropy definition | dS = δQrev / T | Entropy measures how spread out (disordered) the energy is. |
| Entropy principle | ΔSuniverse = ΔSsystem + ΔSsurroundings ≥ 0 | Never negative. It is zero only for a reversible process. |
| Heat reservoir | ΔS = Q / T | A big reservoir stays at constant temperature. |
| Phase change at constant T | ΔS = m hfg / Tsat | Boiling or condensing at one temperature. |
| Ideal gas (T and v) | s2 − s1 = cv ln(T2/T1) + R ln(v2/v1) | Use when volume is known. |
| Ideal gas (T and P) | s2 − s1 = cp ln(T2/T1) − R ln(P2/P1) | Use when pressure is known. |
| Liquid or solid | ΔS = m c ln(T2/T1) | Specific heat c is almost constant. |
| Turbine isentropic efficiency | ηT = (h1 − h2) / (h1 − h2s) | Actual work output ÷ ideal work output. |
| Compressor isentropic efficiency | ηC = (h2s − h1) / (h2 − h1) | Ideal work input ÷ actual work input. |
| Maximum work from heat | Wmax = Q (1 − T0/T) | T0 = surroundings temperature. Called available energy. |
| Irreversibility | I = T0 Sgen | Work lost because the process was not reversible. |
7. Steam and pure substances
| Quantity | Formula | In simple words |
|---|---|---|
| Dryness fraction | x = mg / (mf + mg) | x = 0 is saturated liquid, x = 1 is saturated vapour. Use it only in the wet region. |
| Specific volume (wet steam) | v = vf + x vfg | Mix of liquid and vapour volumes. |
| Enthalpy (wet steam) | h = hf + x hfg | hfg is the latent heat of vaporisation. |
| Entropy (wet steam) | s = sf + x sfg | Same idea as enthalpy. |
| Internal energy | u = h − Pv | Find u after you know h. |
| Superheated steam | h ≈ hg + cp (T − Tsat), cp ≈ 2.1 kJ/kg·K | Quick estimate when tables are not available. |
| Degree of superheat | T − Tsat | How many degrees above the boiling point. |
| Critical point of water | About 374 °C and 22.1 MPa | Above this, liquid and vapour are no longer separate. |
| Throttling calorimeter | h1 = h2, then x = (h2 − hf) / hfg | Find the dryness of wet steam by throttling it to a superheated state. |
8. Engine and refrigeration cycles
| Cycle | Efficiency or COP | What the symbols mean |
|---|---|---|
| Otto (petrol engine) | η = 1 − 1 / rγ−1 | r = V1 / V2 = compression ratio. |
| Diesel | η = 1 − (1 / rγ−1) × (ργ − 1) / [γ (ρ − 1)] | ρ = V3 / V2 = cut-off ratio. |
| Dual | η = 1 − (1 / rγ−1) × (αβγ − 1) / [(α − 1) + γα (β − 1)] | α = P3 / P2 (pressure ratio), β = V4 / V3 (cut-off ratio). |
| Brayton (gas turbine) | η = 1 − 1 / rp(γ−1)/γ | rp = P2 / P1. Net work = cp[(T3 − T4) − (T2 − T1)]. |
| Rankine (steam power plant) | η = [(h1 − h2) − (h4 − h3)] / (h1 − h4) | 1 = turbine inlet, 2 = turbine exit, 3 = condenser exit (saturated liquid), 4 = pump exit. |
| Pump work in Rankine cycle | WP = vf (Pboiler − Pcondenser), h4 = h3 + WP | Pump work is tiny compared with turbine work. |
| Specific steam consumption | SSC = 3600 / Wnet kg/kWh | Steam needed to produce 1 kWh. Wnet in kJ/kg. |
| Vapour compression refrigeration | COP = (h1 − h4) / (h2 − h1) | 1 = evaporator exit, 2 = compressor exit, 3 = condenser exit, 4 = after throttle valve (h4 = h3). |
| Refrigerating effect | h1 − h4 kJ/kg | Cooling produced by each kg of refrigerant. |
| Ton of refrigeration | 1 TR = 3.517 kW = 211 kJ/min | Standard unit of cooling capacity. |
| Mean effective pressure | mep = Wnet / (V1 − V2) | Constant pressure that would give the same work over the swept volume. |
| Which cycle is better? | Same compression ratio: Otto > Diesel. Same maximum pressure and temperature: Diesel > Otto. | A very common exam question. |
9. Gas mixtures
| Quantity | Formula | In simple words |
|---|---|---|
| Dalton’s law | P = P1 + P2 + …, and Pi = xi P | Each gas behaves as if it alone filled the container. |
| Mole fraction | xi = ni / n | Share of each gas by number of moles. |
| Molar mass of mixture | M = Σ xi Mi | Weighted average of the gases. |
| Gas constant of mixture | Rmix = Ru / M | Use it in PV = mRT for the mixture. |
10. Worked examples
Example 1 – Adiabatic compression. 1 kg of air at 1 bar and 300 K is compressed reversibly and adiabatically to 5 bar. Find the final temperature and work input (γ = 1.4, R = 0.287 kJ/kg·K).
Step 1. T2 = T1 (P2/P1)(γ−1)/γ = 300 × 50.2857 = 300 × 1.584 ≈ 475 K.
Step 2. W = mR (T1 − T2)/(γ − 1) = 0.287 × (300 − 475.2)/0.4 ≈ −125.7 kJ.
The negative sign means work is done on the gas, so the work input is about 125.7 kJ.
Step 1. T2 = T1 (P2/P1)(γ−1)/γ = 300 × 50.2857 = 300 × 1.584 ≈ 475 K.
Step 2. W = mR (T1 − T2)/(γ − 1) = 0.287 × (300 − 475.2)/0.4 ≈ −125.7 kJ.
The negative sign means work is done on the gas, so the work input is about 125.7 kJ.
Example 2 – Otto cycle efficiency. An Otto engine has a compression ratio of 8. Find the air-standard efficiency (γ = 1.4).
η = 1 − 1 / 80.4 = 1 − 1 / 2.297 = 1 − 0.435 = 0.565, so η ≈ 56.5%.
Real engines give less, because of friction and heat loss. Raising r raises η.
η = 1 − 1 / 80.4 = 1 − 1 / 2.297 = 1 − 0.435 = 0.565, so η ≈ 56.5%.
Real engines give less, because of friction and heat loss. Raising r raises η.
Example 3 – Is this engine possible? A heat engine takes 500 kJ from a source at 800 K, gives 300 kJ to a sink at 300 K and produces 200 kJ of work.
Check 1 (Carnot limit): ηCarnot = 1 − 300/800 = 62.5%. The engine’s η = 200/500 = 40%, which is less than 62.5%, so it passes.
Check 2 (entropy): ΔS = −500/800 + 300/300 = −0.625 + 1 = +0.375 kJ/K. It is positive, so the engine is possible but irreversible.
Check 1 (Carnot limit): ηCarnot = 1 − 300/800 = 62.5%. The engine’s η = 200/500 = 40%, which is less than 62.5%, so it passes.
Check 2 (entropy): ΔS = −500/800 + 300/300 = −0.625 + 1 = +0.375 kJ/K. It is positive, so the engine is possible but irreversible.
11. Common mistakes to avoid
- Using °C instead of K. Gas laws, Carnot efficiency and entropy all need kelvin.
- Using gauge pressure. Add atmospheric pressure first.
- Mixing kJ and J. In the nozzle and SFEE, V²/2 is in J/kg, so divide by 1000 to get kJ/kg.
- Thinking ΔU = m cv ΔT works only at constant volume. For an ideal gas it works for every process.
- Wrong sign of work. Work done by the system is positive, so a compressor has negative W.
- Using dryness fraction x outside the wet region. For superheated steam, x has no meaning.
- Using γ = 1.4 for steam. The γ = 1.4 value is for air and ideal diatomic gases. Steam needs steam tables.
Prepared by Engineers R World. Free to share for study. Website: engineersrworld.com · Email: engineersrworld@gmail.com · WhatsApp: +91 89197 41799