Heat Transfer Formula Sheet – Easy Explanations & Examples (Free PDF)

Engineers R World – Heat Transfer Formula Sheet  |  engineersrworld.com  |  engineersrworld@gmail.com  |  WhatsApp: +91 89197 41799
Free heat transfer formulas, explained in simple words
9 topics70+ formulas3 solved examplesCommon mistakesFree PDF

Quick answer: This heat transfer formula sheet gives you every formula you need for engineering exams and GATE in one place: conduction, fins, transient conduction, forced and natural convection, radiation, heat exchangers, and boiling and condensation. Each formula comes with a one-line meaning in simple words, so you know when to use it.

Before you start: use SI units and kelvin in radiation formulas. Remember that k (W/m·K) is a material property and h (W/m²·K) is the convection coefficient. Treat heat flow like current in a circuit and add the resistances.

Which formula do I start with?

If the question is about…Start with
Heat through a wall, pipe or sphereSteady conduction (Section 2)
Fins or extended surfacesFins (Section 3)
A hot body cooling suddenlyTransient conduction (Section 4)
Flow over a plate or inside a pipe, finding hForced convection (Section 5)
Heat loss from a vertical wall or hot pipe in still airNatural convection (Section 6)
Heat between hot surfaces, furnaces, shieldsRadiation (Section 7)
Sizing or rating a heat exchangerHeat exchangers (Section 8)
Boiling or condensationBoiling and condensation (Section 9)

1. Basic laws of heat transfer

QuantityFormulaIn simple words
Fourier’s law (conduction)Q = −k A (dT/dx)Heat flows from hot to cold. Larger k means better conductor.
Newton’s law of cooling (convection)Q = h A (Ts − T∞)h = convection coefficient, in W/m²·K.
Stefan–Boltzmann law (radiation)Eb = σ T⁴, with σ = 5.67 × 10−8 W/m²·K⁴Temperature must be in kelvin. A real surface emits ε σ T⁴.
Thermal diffusivityα = k / (ρ cp)How fast a temperature change spreads through a material.
Thermal resistanceR = ΔT / QWorks like Ohm’s law: temperature difference is the voltage, heat flow is the current.

2. Steady conduction

QuantityFormulaIn simple words
Plane wallQ = k A (T1 − T2) / L, R = L / (k A)L = thickness.
Cylinder (pipe wall)Q = 2π k L (T1 − T2) / ln(r2/r1), R = ln(r2/r1) / (2π k L)Here L is the pipe length. Use radius, not diameter.
SphereQ = 4π k (T1 − T2) / (1/r1 − 1/r2), R = (r2 − r1) / (4π k r1 r2)Used for spherical tanks and shells.
Convection resistanceR = 1 / (h A)Add it to the wall resistances in series.
Layers in seriesRtotal = R1 + R2 + …Same Q through every layer.
Overall coefficient (wall)1/U = 1/h1 + L/k + 1/h2, Q = U A ΔTUse for a wall between two fluids.
Critical radius of insulationCylinder: rc = k / h. Sphere: rc = 2k / hInsulation thinner than this can increase heat loss.
Heat generation: plane wallTmax − Ts = qg L² / (2k)L = half thickness. qg = heat generated per unit volume.
Heat generation: cylinder, sphereT0 − Ts = qg R² / (4k) and qg R² / (6k)R = outer radius of the solid.
Easy way to remember: heat flow is like current in a circuit. Add the resistances in series, then Q = ΔT / Rtotal.

3. Fins

QuantityFormulaIn simple words
Fin parameterm = √(h P / (k Ac))P = perimeter, Ac = cross-section area.
Very long finQ = √(h P k Ac) θ0θ0 = Tbase − T∞.
Fin with insulated tipQ = √(h P k Ac) θ0 tanh(m L)Most common textbook case.
Fin efficiencyη = actual heat transfer / heat transfer if the whole fin were at base temperatureAlways less than 1.
Fin effectivenessε = Qfin / (h Ac θ0)A fin is worth adding only if ε is greater than 2.

4. Transient conduction

QuantityFormulaIn simple words
Characteristic lengthLc = V / AsSphere: D/6. Long cylinder: D/4. Plate: half thickness.
Biot numberBi = h Lc / kCompares surface resistance with internal resistance.
Lumped system conditionBi < 0.1The body has almost the same temperature everywhere.
Lumped cooling(T − T∞) / (Ti − T∞) = e−t/τTi = starting temperature.
Time constantτ = ρ V c / (h As)After one τ, the temperature difference falls to 36.8%.
Fourier numberFo = α t / Lc²Dimensionless time.

5. Forced convection

QuantityFormulaIn simple words
Reynolds numberRe = ρ V L / μLaminar or turbulent. In pipes, laminar below 2300.
Prandtl numberPr = μ cp / k = ν / αFluid property. Air is about 0.7, water about 7.
Nusselt numberNu = h L / kDimensionless heat transfer coefficient.
Flat plate, laminar (local)Nux = 0.332 Rex1/2 Pr1/3Rex below 5 × 10⁵.
Flat plate, laminar (average)NuL = 0.664 ReL1/2 Pr1/3Twice the local value at x = L.
Flat plate, turbulent (local)Nux = 0.0296 Rex0.8 Pr1/3Rex above 5 × 10⁵.
Pipe, laminar, fully developedNu = 3.66 (constant wall temperature), Nu = 4.36 (constant heat flux)Independent of Re. Use Nu = hD/k.
Pipe, turbulent (Dittus–Boelter)Nu = 0.023 Re0.8 Prnn = 0.4 for heating, 0.3 for cooling. Use for Re above 10⁴.
Energy balance for pipe flowQ = ṁ cp (Tout − Tin)Heat gained by the fluid.
Want the whole sheet on your phone?

Get the free PDF with all 9 topics, worked examples and common mistakes. Good for revision before exams.

Download free PDF (7 pages)

6. Natural convection

QuantityFormulaIn simple words
Grashof numberGr = g β ΔT L³ / ν²Buoyancy force compared with viscous force.
Rayleigh numberRa = Gr × PrDecides the flow regime.
Expansion coefficient (ideal gas)β = 1 / TT in kelvin.
Vertical plate, laminarNu = 0.59 Ra1/410⁴ < Ra < 10⁹.
Vertical plate, turbulentNu = 0.1 Ra1/3Ra above 10⁹.
Which effect matters?Gr / Re² well above 1: natural. Well below 1: forced. About 1: mixedCompare before choosing a correlation.

7. Radiation

QuantityFormulaIn simple words
Real surface emissionE = ε σ T⁴ε = emissivity, between 0 and 1. Black body has ε = 1.
Kirchhoff’s lawα = εGood emitters are good absorbers (grey surface).
Absorptivity, reflectivity, transmissivityα + ρ + τ = 1Opaque body: α + ρ = 1.
Wien’s displacement lawλmax T = 2898 μm·KHotter bodies emit at shorter wavelengths.
Small body in a large enclosureQ = ε σ A (T1⁴ − T2⁴)Temperatures in kelvin.
Two large parallel platesQ/A = σ (T1⁴ − T2⁴) / (1/ε1 + 1/ε2 − 1)Both plates are grey.
Radiation shieldsQ with n shields = Q without shield / (n + 1)For shields of the same emissivity as the plates.
View factor rulesA1F12 = A2F21, ΣF1j = 1Reciprocity and summation rules.
Radiation network resistancesSurface: (1 − ε) / (ε A). Space: 1 / (A1F12)Draw the circuit, then add resistances.

8. Heat exchangers

QuantityFormulaIn simple words
Energy balanceQ = ṁh cph (Th,in − Th,out) = ṁc cpc (Tc,out − Tc,in)Heat lost by hot fluid equals heat gained by cold fluid.
LMTD methodQ = U A ΔTlmUse when all four temperatures are known.
Log mean temperature differenceΔTlm = (ΔT1 − ΔT2) / ln(ΔT1/ΔT2)ΔT1 and ΔT2 are the differences at the two ends.
Counterflow endsΔT1 = Th,in − Tc,out, ΔT2 = Th,out − Tc,inCounterflow gives the highest ΔTlm.
Parallel flow endsΔT1 = Th,in − Tc,in, ΔT2 = Th,out − Tc,outBoth fluids enter at the same end.
Heat capacity rateC = ṁ cp, Cr = Cmin / CmaxThe smaller C changes temperature more.
Effectivenessε = Q / Qmax, Qmax = Cmin (Th,in − Tc,in)Fraction of the maximum possible heat transfer.
NTUNTU = U A / CminSize of the exchanger. Use the ε-NTU method when outlet temperatures are unknown.
Counterflow effectivenessε = [1 − e−NTU(1 − Cr)] / [1 − Cr e−NTU(1 − Cr)]For Cr = 1: ε = NTU / (1 + NTU).
Parallel-flow effectivenessε = [1 − e−NTU(1 + Cr)] / (1 + Cr)Lower than counterflow.
Boiler or condenser (Cr = 0)ε = 1 − e−NTUSame for every flow arrangement.
Fouling1/U = 1/Uclean + RfDirt on the surface adds resistance.
Quick check: Learnt the formulas? Test yourself with our 100 heat transfer MCQs with answers, or revise with viva questions.

9. Boiling and condensation

TopicKey pointIn simple words
Boiling curve orderNatural convection → nucleate → transition → film boilingAs the surface gets hotter, the regime changes.
Critical heat fluxPeak of the nucleate boiling regionGo beyond it and the surface can burn out.
Leidenfrost pointMinimum heat flux in film boilingA vapour film insulates the surface.
Film and dropwise condensationDropwise h is 5 to 10 times higherDrops roll off and leave bare surface. Film acts as extra resistance.

10. Worked examples

Example 1 – Furnace wall. A furnace wall has 0.2 m of firebrick (k = 1.0 W/m·K) and 0.1 m of insulation (k = 0.1 W/m·K). The inside is at 800 °C and the outside at 100 °C. Find the heat loss per m² and the temperature between the layers.

Step 1. R1 = 0.2/1.0 = 0.2 and R2 = 0.1/0.1 = 1.0 m²·K/W. Rtotal = 1.2.
Step 2. Q/A = 700 / 1.2 ≈ 583 W/m².
Step 3. Interface temperature = 800 − 583.3 × 0.2 ≈ 683 °C.
Example 2 – Cooling steel ball. A 20 mm steel ball (k = 45 W/m·K, ρ = 7800 kg/m³, c = 480 J/kg·K) at 400 °C is cooled in air at 30 °C with h = 50 W/m²·K. How long to reach 100 °C?

Step 1. Lc = D/6 = 0.00333 m. Bi = 50 × 0.00333 / 45 = 0.0037, which is below 0.1, so the lumped method is valid.
Step 2. τ = ρ c Lc / h = 7800 × 480 × 0.00333 / 50 ≈ 250 s.
Step 3. (100 − 30)/(400 − 30) = 0.189, so t = −τ ln(0.189) ≈ 250 × 1.665 ≈ 416 s, about 7 minutes.
Example 3 – Counterflow heat exchanger. Hot oil cools from 150 °C to 90 °C. Water heats from 30 °C to 70 °C. The heat duty is 20 kW and U = 400 W/m²·K. Find the area.

Step 1. Counterflow: ΔT1 = 150 − 70 = 80 K and ΔT2 = 90 − 30 = 60 K.
Step 2. ΔTlm = (80 − 60) / ln(80/60) = 20 / 0.2877 ≈ 69.5 K.
Step 3. A = Q / (U ΔTlm) = 20 000 / (400 × 69.5) ≈ 0.72 m².

11. Common mistakes to avoid

  • Using °C in radiation. The T⁴ law needs kelvin.
  • Using diameter instead of radius. Cylinder and sphere resistances use radii.
  • Mixing k and h. k (W/m·K) is a material property. h (W/m²·K) depends on the flow.
  • Wrong length in the Biot number. Use Lc = V/As, not the full size.
  • Swapping the LMTD end differences. Pair the temperatures correctly for counterflow and parallel flow.
  • Using Dittus–Boelter at low Re. It is valid only for fully turbulent flow, Re above 10⁴.
  • Adding insulation below the critical radius. On thin pipes this can increase heat loss.
Download the Heat Transfer Formula Sheet (PDF)

Free to share with your classmates. Includes every formula, simple explanations and 3 solved examples.

Download free PDF (7 pages)

Frequently Asked Questions

Which heat transfer formulas are the most important for exams?

Learn Fourier’s law, the thermal resistance method for walls and pipes, the lumped capacity equation, the Nusselt number correlations, the Stefan–Boltzmann law, and the LMTD and effectiveness-NTU methods for heat exchangers.

What is the difference between conduction, convection and radiation?

Conduction is heat flow through a solid or still fluid. Convection is heat carried by a moving fluid. Radiation is heat carried by electromagnetic waves and needs no medium.

When can I use the lumped capacity method?

Use it when the Biot number Bi = hLc/k is below 0.1. Then the body is nearly the same temperature everywhere and cools exponentially with time constant τ.

Why is counterflow better than parallel flow?

In counterflow the temperature difference stays more even along the exchanger, so the log mean temperature difference is larger. The same duty needs a smaller area.

Can I download this heat transfer formula sheet?

Yes. Use the Download PDF button in the middle or at the bottom of this page to get the free PDF. You can share it with your classmates.

Prepared by Engineers R World. Free to share for study. Website: engineersrworld.com · Email: engineersrworld@gmail.com · WhatsApp: +91 89197 41799
Scroll to Top