Quick answer: This heat transfer formula sheet gives you every formula you need for engineering exams and GATE in one place: conduction, fins, transient conduction, forced and natural convection, radiation, heat exchangers, and boiling and condensation. Each formula comes with a one-line meaning in simple words, so you know when to use it.
Which formula do I start with?
| If the question is about… | Start with |
|---|---|
| Heat through a wall, pipe or sphere | Steady conduction (Section 2) |
| Fins or extended surfaces | Fins (Section 3) |
| A hot body cooling suddenly | Transient conduction (Section 4) |
| Flow over a plate or inside a pipe, finding h | Forced convection (Section 5) |
| Heat loss from a vertical wall or hot pipe in still air | Natural convection (Section 6) |
| Heat between hot surfaces, furnaces, shields | Radiation (Section 7) |
| Sizing or rating a heat exchanger | Heat exchangers (Section 8) |
| Boiling or condensation | Boiling and condensation (Section 9) |
1. Basic laws of heat transfer
| Quantity | Formula | In simple words |
|---|---|---|
| Fourier’s law (conduction) | Q = −k A (dT/dx) | Heat flows from hot to cold. Larger k means better conductor. |
| Newton’s law of cooling (convection) | Q = h A (Ts − T∞) | h = convection coefficient, in W/m²·K. |
| Stefan–Boltzmann law (radiation) | Eb = σ T⁴, with σ = 5.67 × 10−8 W/m²·K⁴ | Temperature must be in kelvin. A real surface emits ε σ T⁴. |
| Thermal diffusivity | α = k / (ρ cp) | How fast a temperature change spreads through a material. |
| Thermal resistance | R = ΔT / Q | Works like Ohm’s law: temperature difference is the voltage, heat flow is the current. |
2. Steady conduction
| Quantity | Formula | In simple words |
|---|---|---|
| Plane wall | Q = k A (T1 − T2) / L, R = L / (k A) | L = thickness. |
| Cylinder (pipe wall) | Q = 2π k L (T1 − T2) / ln(r2/r1), R = ln(r2/r1) / (2π k L) | Here L is the pipe length. Use radius, not diameter. |
| Sphere | Q = 4π k (T1 − T2) / (1/r1 − 1/r2), R = (r2 − r1) / (4π k r1 r2) | Used for spherical tanks and shells. |
| Convection resistance | R = 1 / (h A) | Add it to the wall resistances in series. |
| Layers in series | Rtotal = R1 + R2 + … | Same Q through every layer. |
| Overall coefficient (wall) | 1/U = 1/h1 + L/k + 1/h2, Q = U A ΔT | Use for a wall between two fluids. |
| Critical radius of insulation | Cylinder: rc = k / h. Sphere: rc = 2k / h | Insulation thinner than this can increase heat loss. |
| Heat generation: plane wall | Tmax − Ts = qg L² / (2k) | L = half thickness. qg = heat generated per unit volume. |
| Heat generation: cylinder, sphere | T0 − Ts = qg R² / (4k) and qg R² / (6k) | R = outer radius of the solid. |
3. Fins
| Quantity | Formula | In simple words |
|---|---|---|
| Fin parameter | m = √(h P / (k Ac)) | P = perimeter, Ac = cross-section area. |
| Very long fin | Q = √(h P k Ac) θ0 | θ0 = Tbase − T∞. |
| Fin with insulated tip | Q = √(h P k Ac) θ0 tanh(m L) | Most common textbook case. |
| Fin efficiency | η = actual heat transfer / heat transfer if the whole fin were at base temperature | Always less than 1. |
| Fin effectiveness | ε = Qfin / (h Ac θ0) | A fin is worth adding only if ε is greater than 2. |
4. Transient conduction
| Quantity | Formula | In simple words |
|---|---|---|
| Characteristic length | Lc = V / As | Sphere: D/6. Long cylinder: D/4. Plate: half thickness. |
| Biot number | Bi = h Lc / k | Compares surface resistance with internal resistance. |
| Lumped system condition | Bi < 0.1 | The body has almost the same temperature everywhere. |
| Lumped cooling | (T − T∞) / (Ti − T∞) = e−t/τ | Ti = starting temperature. |
| Time constant | τ = ρ V c / (h As) | After one τ, the temperature difference falls to 36.8%. |
| Fourier number | Fo = α t / Lc² | Dimensionless time. |
5. Forced convection
| Quantity | Formula | In simple words |
|---|---|---|
| Reynolds number | Re = ρ V L / μ | Laminar or turbulent. In pipes, laminar below 2300. |
| Prandtl number | Pr = μ cp / k = ν / α | Fluid property. Air is about 0.7, water about 7. |
| Nusselt number | Nu = h L / k | Dimensionless heat transfer coefficient. |
| Flat plate, laminar (local) | Nux = 0.332 Rex1/2 Pr1/3 | Rex below 5 × 10⁵. |
| Flat plate, laminar (average) | NuL = 0.664 ReL1/2 Pr1/3 | Twice the local value at x = L. |
| Flat plate, turbulent (local) | Nux = 0.0296 Rex0.8 Pr1/3 | Rex above 5 × 10⁵. |
| Pipe, laminar, fully developed | Nu = 3.66 (constant wall temperature), Nu = 4.36 (constant heat flux) | Independent of Re. Use Nu = hD/k. |
| Pipe, turbulent (Dittus–Boelter) | Nu = 0.023 Re0.8 Prn | n = 0.4 for heating, 0.3 for cooling. Use for Re above 10⁴. |
| Energy balance for pipe flow | Q = ṁ cp (Tout − Tin) | Heat gained by the fluid. |
6. Natural convection
| Quantity | Formula | In simple words |
|---|---|---|
| Grashof number | Gr = g β ΔT L³ / ν² | Buoyancy force compared with viscous force. |
| Rayleigh number | Ra = Gr × Pr | Decides the flow regime. |
| Expansion coefficient (ideal gas) | β = 1 / T | T in kelvin. |
| Vertical plate, laminar | Nu = 0.59 Ra1/4 | 10⁴ < Ra < 10⁹. |
| Vertical plate, turbulent | Nu = 0.1 Ra1/3 | Ra above 10⁹. |
| Which effect matters? | Gr / Re² well above 1: natural. Well below 1: forced. About 1: mixed | Compare before choosing a correlation. |
7. Radiation
| Quantity | Formula | In simple words |
|---|---|---|
| Real surface emission | E = ε σ T⁴ | ε = emissivity, between 0 and 1. Black body has ε = 1. |
| Kirchhoff’s law | α = ε | Good emitters are good absorbers (grey surface). |
| Absorptivity, reflectivity, transmissivity | α + ρ + τ = 1 | Opaque body: α + ρ = 1. |
| Wien’s displacement law | λmax T = 2898 μm·K | Hotter bodies emit at shorter wavelengths. |
| Small body in a large enclosure | Q = ε σ A (T1⁴ − T2⁴) | Temperatures in kelvin. |
| Two large parallel plates | Q/A = σ (T1⁴ − T2⁴) / (1/ε1 + 1/ε2 − 1) | Both plates are grey. |
| Radiation shields | Q with n shields = Q without shield / (n + 1) | For shields of the same emissivity as the plates. |
| View factor rules | A1F12 = A2F21, ΣF1j = 1 | Reciprocity and summation rules. |
| Radiation network resistances | Surface: (1 − ε) / (ε A). Space: 1 / (A1F12) | Draw the circuit, then add resistances. |
8. Heat exchangers
| Quantity | Formula | In simple words |
|---|---|---|
| Energy balance | Q = ṁh cph (Th,in − Th,out) = ṁc cpc (Tc,out − Tc,in) | Heat lost by hot fluid equals heat gained by cold fluid. |
| LMTD method | Q = U A ΔTlm | Use when all four temperatures are known. |
| Log mean temperature difference | ΔTlm = (ΔT1 − ΔT2) / ln(ΔT1/ΔT2) | ΔT1 and ΔT2 are the differences at the two ends. |
| Counterflow ends | ΔT1 = Th,in − Tc,out, ΔT2 = Th,out − Tc,in | Counterflow gives the highest ΔTlm. |
| Parallel flow ends | ΔT1 = Th,in − Tc,in, ΔT2 = Th,out − Tc,out | Both fluids enter at the same end. |
| Heat capacity rate | C = ṁ cp, Cr = Cmin / Cmax | The smaller C changes temperature more. |
| Effectiveness | ε = Q / Qmax, Qmax = Cmin (Th,in − Tc,in) | Fraction of the maximum possible heat transfer. |
| NTU | NTU = U A / Cmin | Size of the exchanger. Use the ε-NTU method when outlet temperatures are unknown. |
| Counterflow effectiveness | ε = [1 − e−NTU(1 − Cr)] / [1 − Cr e−NTU(1 − Cr)] | For Cr = 1: ε = NTU / (1 + NTU). |
| Parallel-flow effectiveness | ε = [1 − e−NTU(1 + Cr)] / (1 + Cr) | Lower than counterflow. |
| Boiler or condenser (Cr = 0) | ε = 1 − e−NTU | Same for every flow arrangement. |
| Fouling | 1/U = 1/Uclean + Rf | Dirt on the surface adds resistance. |
9. Boiling and condensation
| Topic | Key point | In simple words |
|---|---|---|
| Boiling curve order | Natural convection → nucleate → transition → film boiling | As the surface gets hotter, the regime changes. |
| Critical heat flux | Peak of the nucleate boiling region | Go beyond it and the surface can burn out. |
| Leidenfrost point | Minimum heat flux in film boiling | A vapour film insulates the surface. |
| Film and dropwise condensation | Dropwise h is 5 to 10 times higher | Drops roll off and leave bare surface. Film acts as extra resistance. |
10. Worked examples
Step 1. R1 = 0.2/1.0 = 0.2 and R2 = 0.1/0.1 = 1.0 m²·K/W. Rtotal = 1.2.
Step 2. Q/A = 700 / 1.2 ≈ 583 W/m².
Step 3. Interface temperature = 800 − 583.3 × 0.2 ≈ 683 °C.
Step 1. Lc = D/6 = 0.00333 m. Bi = 50 × 0.00333 / 45 = 0.0037, which is below 0.1, so the lumped method is valid.
Step 2. τ = ρ c Lc / h = 7800 × 480 × 0.00333 / 50 ≈ 250 s.
Step 3. (100 − 30)/(400 − 30) = 0.189, so t = −τ ln(0.189) ≈ 250 × 1.665 ≈ 416 s, about 7 minutes.
Step 1. Counterflow: ΔT1 = 150 − 70 = 80 K and ΔT2 = 90 − 30 = 60 K.
Step 2. ΔTlm = (80 − 60) / ln(80/60) = 20 / 0.2877 ≈ 69.5 K.
Step 3. A = Q / (U ΔTlm) = 20 000 / (400 × 69.5) ≈ 0.72 m².
11. Common mistakes to avoid
- Using °C in radiation. The T⁴ law needs kelvin.
- Using diameter instead of radius. Cylinder and sphere resistances use radii.
- Mixing k and h. k (W/m·K) is a material property. h (W/m²·K) depends on the flow.
- Wrong length in the Biot number. Use Lc = V/As, not the full size.
- Swapping the LMTD end differences. Pair the temperatures correctly for counterflow and parallel flow.
- Using Dittus–Boelter at low Re. It is valid only for fully turbulent flow, Re above 10⁴.
- Adding insulation below the critical radius. On thin pipes this can increase heat loss.
Frequently Asked Questions
Which heat transfer formulas are the most important for exams?
Learn Fourier’s law, the thermal resistance method for walls and pipes, the lumped capacity equation, the Nusselt number correlations, the Stefan–Boltzmann law, and the LMTD and effectiveness-NTU methods for heat exchangers.
What is the difference between conduction, convection and radiation?
Conduction is heat flow through a solid or still fluid. Convection is heat carried by a moving fluid. Radiation is heat carried by electromagnetic waves and needs no medium.
When can I use the lumped capacity method?
Use it when the Biot number Bi = hLc/k is below 0.1. Then the body is nearly the same temperature everywhere and cools exponentially with time constant τ.
Why is counterflow better than parallel flow?
In counterflow the temperature difference stays more even along the exchanger, so the log mean temperature difference is larger. The same duty needs a smaller area.
Can I download this heat transfer formula sheet?
Yes. Use the Download PDF button in the middle or at the bottom of this page to get the free PDF. You can share it with your classmates.